Wrimco Waterproofing                              Home  | Specification | Product | Project | Technical data A-Z | Contact us

Adhesive Membrane

Anti-root Membrane

Approved Applicators

Backing Rod

Drainage Cell

Drainage Sheet

Epoxy Adhesive

Epoxy Flooring

Flat Roof Membrane  

Foundation Membrane

Liquid Membrane

Membrane Protection

Product Application

Product Category

Retaining Wall

SBS Sheet Membrane

Torch on Membrane

Under Slab Membrane

Vapour Barriers

Waterproofing Primer

 

Waterproof Balcony Liquid Membrane Waterproof Bathroom liquid membrane Waterproof Retaining Wall Liquid Rubber Membrane How to waterproof a bathroom Waterproof Internal Wet Area Membrane Waterproof Tiled Balcony Clear Penetrating Sealer Trafficable liquid membrane UV Protection liquid membrane Waterproof Water Feature liquid membrane Hydro Pressure Resistant liquid membrane Waterproof Shower Recess liquid membrane Repair Roof Gutters liquid Membrane Waterproof Planter Box liquid membrane Waterproof Under Tiles Liquid Membrane Waterproof Water Tanks liquid membrane waterproof Flat Roof liquid membrane Waterproof fish pond liquid membrane Waterproof Swimming Pool  How to stop tiled deck leaking waterproof bathroom liquid membrane Waterproof Leaking Shower Tradesman Waterproof Leaking Balcony Liquid Membrane Waterproof Damp Basement Wall Liquid Membrane Crystoflex Max Cementetious waterproofing membrane Waterproof Under Screed Liquid Membrane Waterproof above screed liquid membrane How to waterproof a Planter Box How to waterproof a shower How to waterproof tiled balcony Waterproof Roofs with UV liquid membrane How to waterproof a metal roof Sikalastic 560 - Repair Bitumen membrane Roof How to waterproof a planter box Waterproof Flat roof liquid membrane Below Grade Membrane UV Resistant Polyurethane Membrane Waterproof leaking balcony liquid membrane waterproof damp basement wall liquid membrane Solutions to common waterproofing problems Maxseal Foundation Mapelastic Smart Membrane Polyurethane Membrane MasterSeal M210TIX Latex Rubber Liquid Membrane Waterproof wet basement wall liquid membrane Waterproof leaking Basement Tradesman Waterproof Building Contractors Waterproof Lift Pit Contractors Waterproof leaking Internal Wall tradesman Waterproof leaking deck tradesman waterproof leaking roof, gutters, balcony, car park tradesman Waterproof leaking Box Gutter Tradesmen Waterproof leaking External Wall tradesmen Waterproof Swimming Pool Contractors Waterproof Garage Roof Liquid Membrane Injection Drill Pump Vulkem 350/345/346 Ardex WPM 300 Epoxy - Stop Rising Damp Ardex WPM300 Waterproof Metal Roof Liquid Membrane Waterproof Leaking Under Tiles Liquid Membrane Repair Leaking Balcony, Flat Roof, Planter Box, Bathroom Waterproofer, waterproof Leaking Balcony, Flat Roof, Planter Box, Bathroom tradesman, handyman Waterproof exposed balcony liquid membrane Hydrostatic Pressure resistant Liquid Membrane Waterproof Box gutter liquid membrane Prevent Rising Damp Waterproofing Epoxy Waterproof leaking metal roof tradesman Waterproof Retaining Wall liquid membrane Waterproof Underground Walls liquid membrane Waterproof Internal, External Wall Liquid Membrane Waterproof Concrete Slab Liquid Membrane Waterproof Balcony Liquid Membrane Stop Leaking Shower Liquid Membrane How to repair a leaking fish pond Waterproof Wet Retaining Wall Liquid Membrane Waterproof Aluminium Roof Liquid Membrane How to waterproof a retaining wall How to waterproof a Retaining Wall Waterproof cement screed epoxy Vulkem 360NF Waterproof Car Park Liquid Membrane Waterproof Retaining Wall liquid membrane Waterproof Besser Block Wall Liquid Membrane How to fix leaking fish pond Waterproof Garage Roof Liquid Rubber Membrane Trafficable UV resistant liquid membrane Stop Basement Wall Leaking UV Resistant Polyurethane Liquid Membrane Waterproof water tanks for drinkable water Waterproof Commercial Roof, Balcony Contractors
Commercial Building Sheet Membrane Concrete Roof Sheet Membrane Waterproof Deck Sheet Membrane Entertainment building Waterproofing Membrane Waterproof Government Building Sheet Membrane Waterproof Hospital Building Sheet Membrane Waterproof Landmark Building Bitumen Membrane Waterproofing Planter Box Sheet Membrane Waterproof Plywood Roof Sheet Membrane Waterproof Residential Building Sheet Membrane Waterproof Roof Bitumen Sheet Membrane Waterproof Flat Roof Sheet Membrane Waterproof Retaining Wall Sheet Membrane Terrace waterproofing Sheet Membrane Waterproof University Building Sheet Membrane Wrimco Reference Waterproof Lift Pit Sheet Membrane Waterproof Car Park Roof Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Concrete Roof Sheet Membrane Tanking Sheet Membrane Systems Vaucluse Waterproofing Project  Mosman Waterproofing Project Waterproofing Palm Beach Waterproofing Dover Height Waterproofing Darling Point Waterproofing Bellevue Hill waterproofing tradesman Under Concrete Slab Waterproofing Knowledge Base FAQ Waterproofing Product Waterproof Leaking Swimming pool tradesman Waterproof Leaking Garage Roof tradesman Repair SBS, APP Sheet Membrane Waterproof Concrete Slab Sheet Membrane Waterproof Leaking Garage Roof Liquid Rubber Membrane Waterproof Leaking Metal Roof Liquid Rubber Membrane Polyurethane Modified Acrylic Liquid Rubber Membrane Waterproof Balustrade Sheet Membrane Waterproof Commercial Building Project Bitumen Sheet Membrane Waterproofing Membrane Protection Drainage Cell Closed Cell Backing Rod Repair Crack Joints Closed cell backer rod Expansion joint backing rod Backing Rod waterproof leaking laundry tradesman Repair Leaking underground basement wall Waterproofer Waterproof leaking planter box tradesman Waterproof Leaking Shower Tradesman Waterproof Planter Box Tradesman Waterproof Leaking Box Gutter Tradesman Waterproof Leaking Balcony Tradesman Waterproof Leaking Fish Pond Tradesman Repair Construction Building Contractors

Ardex WPM 310  :


ARDEX WPM 310 - (Shelterguard) External facade and roof membrane  

Product Description  

ARDEX WPM 310 is a tough, UV stable flexible, premixed liquid applied waterproofing membrane. It has been specifically formulated as a general purpose membrane for exposed wall and roof waterproofing. ARDEX WPM 310 can be applied as an aesthetically attractive textured or semi-smooth finish for walls or a semi-smooth uniform finish for roofs. ARDEX WPM 310 is available in a range of standard colours.  

Features/Benefits  

Flexible - accommodates normal building movement.

Provides excellent UV resistance and long term protection from elements.

Excellent workability - easy, quick to apply.

Decorative - choice of colours.

Water based - safe to use, low odour and easy cleaning.  

Typical Uses  

At a dry film thickness of 0.30mm the film formed is classified as semi-permeable and suitable for substrates that have to breathe. As a decorative textured finish and waterproofing of external walls and facades. At a dry film thickness of 1.0mm the film forms a waterproof membrane. As a waterproof membrane over concrete roofs, decks. Suitable for light (service) traffic when fully reinforced and overcoated with ARDEX WPM 355 Protective Finish. High traffic areas will require a protective cement screed over the membrane.  

Limitations  

Do not use the product in the following situations:

Areas subject to traffic must be treated as follows:  

 Light (service) traffic - fully reinforce with ARDEX Deckweb and overcoat with ARDEX WPM 355 (Sheltercoat Protective Finish).

 

 Medium or Heavy traffic - apply a protective cementitious screed over the membrane to provide protection.  

Where solvent or petroleum based products could be spilled.

When rain appears imminent.

Where the surface temperature is below 10oC or greater than 35oC.

On wet surfaces that have not been sealed with ARDEX WPM 300 (HydrEpoxy 300).

Do not attempt to thin with water. For substrates or situations other than those listed, contact your ARDEX representative.  

Surface Preparation  

Ensure all surfaces are structurally sound or securely fixed and totally dry. The surface to be coated should be free from dust, oil, curing compounds and any other contaminating materials. When applying over existing coatings, ensure they are firmly bonded. Damaged or spalled concrete should be repaired with ARDEX B 34 and B 36 fairing coat and patching mortars (levelled) and surface defects including all cracks and sharp protrusions should be treated prior to the application of the membrane. Remove laitance by mechanical means and dense concrete should be mechanically roughened to open the pores of the concrete. New concrete should be left at least 28 days to cure or primed with ARDEX WPM 300 (HydrEpoxy 300). Wet, damp or new concrete substrate surfaces should be primed with ARDEX WPM 300 (HydrEpoxy 300) at 3.0 square metres per litre (0.3mm wet film thickness) and allowed to cure overnight. All surfaces, other than those sealed with ARDEX WPM 300 (HydrEpoxy 300), must be primed with ARDEX WPM 270 solvent or ARDEX WPM 265 water based primer at a coverage rate of 6 square metres per litre. ARDEX WPM 270 solvent based primer is preferred for use in external applications. Hebel block or other highly porous surfaces may need two coats. Allow the primer to dry for at least 30 minutes before applying the first coat of membrane. The primer should preferably be overcoated within the same day of application to avoid intercoat contamination.  

Application  

External Wall Membrane Application  

Apply using a nap or textured roller. Apply the coating in two coats ensuring a uniform coverage is achieved at an approximate wet film thickness of 0.3mm per coat to achieve an overall dry film thickness of 0.3mm. Allow the first coat to become hard dry (normally about 4 hours at 23oC / 50% RH) before applying the second coat.

Roof Membrane Application  

Apply the coating in two coats ensuring a uniform coverage is achieved at an approximate wet film thickness of 1.0mm per coat to achieve an overall dry film thickness of 1.0mm. Allow the first coat to become hard dry (normally about 4 hours at 23oC / 50% RH) before applying the second coat. Cold joints and mobile joints must incorporate a bond breaker and be reinforced using ARDEX Deckweb. Areas subject to light (service) traffic should be fully reinforced using ARDEX Deckweb and overcoated with ARDEX WPM 355 (Sheltercoat Protective Finish). Areas subject to heavy traffic should have a protective cementitious screed applied over the membrane.  

Surface finish  

The surface finish achieved can be varied by selection of method of application. Prior to the commencement of any project it is recommended that a sample of the finish be prepared for approval and that finish shall act as the standard.  

Surface finish profile

Roller type

Roller type  

 

1st coat

2nd coat

High Texture

Med. Texture

Med. Texture

Medium Texture

Nap

Med. Texture  

Low Texture

Med. Texture

Nap

Ripple Texture

Nap

Nap  

The length of the roller nap will vary the profile of the texture although the nap length must suit the substrate. A 10-12mm nap produces a low surface profile while a 15-18mm nap produces a higher surface profile.  

Coverage

External Wall Membrane Application  

1 x 15 litre unit will cover approximately 24 square metres in two coats at a total dry film thickness of 0.3mm.  

Roof Membrane Application  

1 x 15 litre unit will cover approximately 7 square metres in two coats at a total dry film thickness of 1.0mm. Coverage will vary depending on the condition of the surface and film thickness.  

Cleaning and Thinning  

Thinning is not necessary or recommended. Clean up with water before material has set and remove cured material with mineral turps.  

PROPERTY DATA

 

Characteristics of liquid

 

Form and colour

 

Viscous Liquid in standard colours. Special colours on request at a premium

Specific gravity

Approx. 1.3 g/cm3

Characteristics of cured membrane

 

Water vapour transmission  (ASTM E96) at 1.0mm

21.9 g/m2/24hrs  

Tensile strength AS1145

After 28 days dry

After 14 days UV exposure

After 2,500 hrs QUV  

 

2.1 MPa

3.0 MPa

5.9 MPa  

Elongation at break AS1145

After 28 days dry    

After 14 days UV exposure

After 2,500 hrs QUV 

 

460% 

315%

180%

Application details

 

Application method

 

- Textured roller, medium nap roller or brush for external wall membrane.

- Long nap roller or brush for roof membrane application.

Overcoat time

4 hrs at 23oC 50% RH

Dry through (2nd coat)

24 hrs at 23oC 50% RH

Application temperature

10 C - 35oC (surface temp)

Service temperature

0 C - 60oC

VOC content

100g/L

  Safety Data  

Non-hazardous substance. Non-dangerous goods.  

Spills/Leaks  

Clean up spills immediately. Contain and absorb spill with sand, earth, inert material or vermiculite. Wipe up. Place in a suitable labeled container for waste disposal.  

Fire  

Non combustible. Not considered to be a significant fire risk.

 