Wrimco Waterproofing                                             Home | Product | Project | Technical data | Contact us

 

Torch on Membrane

Liquid Membrane

Protection Board

Backing Rod

Cement Adhesive

Drainage Sheet

Product Range 

Company Profile

Licensed Contractor

Membrane Protection

NATSPEC Specification

Product Application 

Roof Waterproofing

SBS Membrane

Waterproof Bathroom

Waterproof Coating

Waterproofing FAQ

Waterproofing Primer

Waterproofing Sealant

 

 

 

 

NP180 pp SBS membrane :

Physical Properties:   
 
Thickness  

0.120 inches (3.0 mm) +/- 10%  

Tensile Strength @ 0 o F  

Machine Direction  

Cross Machine Direction  

100 lbf/inch  

80 lbf/inch  

Elongation @ 0 o F  

Machine Direction  

Cross Machine Direction  

40%  

7%  

Tensile Tear  

Machine Direction  

Cross Machine Direction  

100 lbf/inch  

70 lbf/inch  

Low Temperature Flexibility  

Machine Direction  

Cross Machine Direction  

0 o F  

0 o F  

Dimensional Stability  

Machine Direction  

Cross Machine Direction  

<0.5%  

<0.5%  

Top Surface  

Polyethylene  

Bottom Surface  

Polyethylene  

Thickness  

3.0mm (120 mils)  

Roll Length  

32.9 ft.  

Roll Width  

39 3/8"  

Gross Coverage  

107.6 ft2  

Net Coverage  

98 ft2  

  
Approvals & Certifications  

 

UL listed for Class A and B fire rated roof coverings.  

FM approved. Subject to the conditions of approval as a roof coating when installed as described in the current edition of the FMRC approval guide.  

Consult UL and FM listings.  

 

Uses:  
modified PLUS NP180p/p Base Sheet is designed for use as the base or first ply in a high performance two-ply modified bitumen system, or as a single ply when not exposed, and for fillets and detailing. Main applications are for tanking, balconies and roofing and for waterproofing of planters.  
  

Features:  

SBS polymer provides flow resistance at high temperatures and flexibility at low temperatures for lasting durability.  

Non-woven polyester 180g/m2 reinforcement.  

Designed for application in new construction, re-roofing and retrofit roofing.  

Excellent tear resistance.  

   

Limitations:  

Non-resistant to oils and solvents. Refer to manufacturer for specific chemical resistance. Not designed for permanent exposure. Install modified PLUS  granule surfaced cap sheet over base sheet for permanent exposure. 
 
 

Storage:  

Store rolls on end, on original pallets or elevated platform. Protect from weather or store in an enclosed area not subject to heat over 120 oF.  

 

Surface Preparation  

Refer to modified PLUS   General Specifications for preparation and acceptable substrates.  

 

Application:  

 

modified PLUS   NP180p/p must be torched or nailed to substrate. Roll out modified PLUS   NP180p/p and allow to relax prior to application.  

Begin application of the base sheet at the lowest edge or drain. Proceed up the slope from the lowest point. Position and unroll base sheet to achieve correct overlap and alignment. Re-roll one end a minimum of 10' and adhere membrane to substrate. Complete application of remainder of sheet.  

 

Torching Application: Heat lower surface of membrane. Sufficient heat must be applied to melt the lower surface and provide a flow of bitumen as the roofing membrane is unrolled. Care should be taken to ensure that heating is even across the width to avoid skips or voids.  

790-11 Application: Torch to primed substrate as described above. Scorch film on top surface prior to over coating with 790-11.  

Slopes 1:12 (1" in 12") or Greater : In addition to the above, apply membrane parallel to direction of slope and blind nail or mechanically fasten membrane at end or head lap on 6" centers
 
 

Contractor | Backer Rod   |    Waterproof membrane    |   Drainage cell   |    Coating    | Protection Board   | Waterproof Bathroom | Waterproofing Primer   | Waterproofing Sealant | XPS Extruded Polystyrene | Phone: (02) 9660 8333  |  Fax: (02) 9692 8600  |  10 Hill Street, Leichhardt NSW 2040 Australia