External Internal Liquid membrane:

DUROMASTIC ACS-2:  CLASS II for Showers, Decks and Balconies
 
CLASS II for Showers, Decks, Roofs and Balconies DUROMASTIC ACS-2 is a two  part liquid / cement copolymer membrane with fibrous reinforcement. DUROMASTIC ACS-2 cures rapidly to form a flexible waterproof lining for showers and other wet areas as described in Australian Standard AS3740:2004 "Waterproofing wet areas within residential buildings" & complies to S4858:2004 "Wet Area Membranes"

DUROMASTIC ACS-2 forms a waterproof lining to most building materials including reinforced concrete, cement   render, water resistant plaster board, and fibre reinforced cement sheet flooring, etc. The surface must be firmly fixed to manufacturers directions, and must be clean and dry. DUROMASTIC ACS-2 is suitable for external use on light pedestrian trafficable decks, parapets and flashings. Top coat with Duro Mastic SR for UV resistance.

 

PRINCIPLE CHARACTERISTICS

 

Simple application, water based

Fast drying

Good flexibility

Seamless, no joints or cracks

Low odour, non toxic

Resistance to foot traffic   

 

USE AREAS

 

Showers and internal wet areas

Decks   

Balconies

Roof tops   

 

GENERAL

 

Coverage

1.7 litres /M2 / 1.2mm DFT

Dry Time

Approx 3hrs@ .8mm WFT@ 22 o C

Colour

Green, Grey (dry)

Recoat Time

2-4 hours @ 25 o C

Wet Film per coat

0.8mmUse within 5 hrs of mixing

Weather resistance

Good

Shelf Life

depending on mix ratio

Mix Ratio

Powder 1kg, Liquid 1 litre

Dry Film Thickness

1.2mm min. total

Elongation at break

295% @ 25 o C

Solids Contents

75% by volume with powder

 

PACKAGING 

 

20 litre liquid + 20 kg powder

10 litre liquid + 10 kg powder

 

CLEANUP

Clean up with fresh water before curing.   

 

Waterproofing Wet Areas with DUROMASTIC ACS-2

 

APPLICATION

 

Step 1:

Remove all dirt, dust, plaster and cement droppings, protrusions, oil and contaminants. Fill screw holes and any voids with neutral cure silicone

 

Step 2:

Apply neutral cure silicone sealant* to all horizontal joints within the area to be waterproofed. To all wall/floor and wall/wall junctions, apply approx 12mm bead of neutral cure silicone as a bond breaker. Apply sealant around floor penetrations, tap fittings and other discontinuities. Floor wastes in concrete shall be cut level with the floor. For sheet flooring, leak control flanges shall be recessed and fully sealed.

 

Step 3:

Prime internal surfaces with DUROSEAL AR or DUROPRIME ARW Primer. External surfaces shall be primed with DUROPRIME WBE. Allow to dry. All PVC to be etch primed.

 

Step 4:

Cracks. Non-movement and hairline cracks may be filled with a brush coat of DUROMASTIC ACS-2. Movement cracks shall be routed out, cleaned and filled with silicone sealant. Apply a polyester reinforcing bandage embedded in DUROMASTIC ACS-2 and allow to dry.   

 

Step 5:

Sheet flooring joints. Apply a 200mm wide reinforced bandage of polyester fibre in DUROMASTIC ACS-2 and allow to dry. Ensure joint movement is not beyond the elastic limited of the membrane.

 

Step 6.         

Mixing. Stir powder component into half the liquid until smooth, stand 5 minutes, re-stir and add the balance of the liquid. DO NOT add water to mixture before or during use. Apply two or more coats of DUROMASTIC ACS-2 to the floor and coved areas to ensure a minimum dry film thickness of 1.2mm. Apply one or two coats to wall areas above the shower tray to a dry film thickness of 0.5mm. Use brush or short nap roller for walls. Ensure the membrane is turned down into the floor waste or well sealed around the leak control flange and other penetrations. Ensure flashing angles are properly sealed across doorways. Check for pinholes, misses or cracks in the membrane when dry and rectify.

 

* PU sealant may be used in place of silicone provided it is fully cured prior to membrane application.

 

TILING

Cured DUROMASTIC ACS-2 may be tiled over using Durohesive range of tile adhesives.   

 

PRECAUTIONS

 

Do not apply above 35C or below 6C. Areas subject to rising damp or back pressure should be first sealed with an epoxy coating such as DUROPOXY WBE (Water Based Epoxy). Cold damp conditions retard cure, allow plenty of air flow to aid drying. Do not apply excessive thickness to internal corners or shrinkage cracking may occur. Make sure that the membrane is fully dry before tiling over, normally 1-3 days. Protect membrane against damage before and during tiling very important on timber floors. Do not apply more than 1.2mm DFT per coat or reduced flexibility will occur.

DUROMASTIC ACS-2 is suitable for tiling over. Use standard cement or water based tile adhesive. Do not use solvent based adhesive/sealers. When tiling externally provide a slip sheet between the membrane and the tile bed and allow sufficient expansion and contraction control joints in overlaying tiles and topping, otherwise the membrane will be damaged. 

 
Duromastic ACS-2 MSDS:
 
Duromastic ACS-2 (Liquid) MSDS

Material Safety Data Sheet

 

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

 

Issue Date: 07/11/2006 Revision Date: 20/10/2007

Not classified as Hazardous according to criteria of NOHSC1 and not Dangerous

Goods according to the ADG2 Code

UN NO: None allocated D.G. Class.: Non Hazardous Pack. Group: None allocated

HAZCHEM: None allocated SUB. RISK.: None allocated SUSDP: None allocated

PROPER SHIPPING NAME : Duromastic ACS 2 (Liquid)

PRODUCT USE: Waterproof Membrane Coating

 

2. COMPOSITION / INFORMATION ON INGREDIENTS

 

Component CAS No Weight %

Latex Emulsion Not Required >60

Titanium dioxide 13463-67-7 <10

Additives Not Required <10

See Section 8, Exposure Controls / Personal Protection

 

3. HAZARDS IDENTIFICATION

 

Not hazardous in normal industrial use.

DUROMASTIC ACS 2 (Liquid)

Duromastic ACS 2 (Liquid) MSDS

 

4. FIRST AID MEASURES

 

Eyes: Immediately flush with water for 15 minutes. Get medical advice if irritation develops or persists.

Skin: Take off all contaminated clothing. Wash contaminated area with soapy warm water. Get medical advice if irritation develops or persists. Wash contaminated clothing and clean shoes before reuse.

Inhalation: Remove to fresh air. If not breathing, give artificial respiration, preferable mouth to mouth. If

breathing is laboured, give oxygen and consult a physician immediately.

Ingestion: Consult a physician immediately. If vomiting occurs, aspiration into the lungs may cause lung damage. Never give anything by mouth to an unconscious person.

 

5. FIRE FIGHTING MEASURES

 

Flash Point ................................................................Not Applicable

Auto-ignition Temperature ..........................................No data available

Lower Explosive Limit .................................................No data available

Upper Explosive Limit .................................................No data available

Suitable Extinguishing Media:

Use as appropriate for surrounding fire.

Protective Equipment for Fire Fighting:

Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes.

Unusual Fire and Explosion Hazards:

The product is not flammable.

Thermal decomposition of this product may produce toxic fumes.

 

6. ACCIDENTAL RELEASE MEASURES

 

Caution: Floor may be slippery. Eliminate all sources of ignition. Provide sufficient ventilation. Wear appropriate personal protective equipment including gloves and safety glasses. Do not breathe vapour. Contain spill. Do not allow into drains or waterways. Take up with absorbent material (e.g. sand, v ermiculite, or commercially available inorganic absorbent). Use non-sparking tools and equipment. Fill into suitable containers for disposal.

Dispose of empty containers in accordance with federal, state and local laws.

 

7. HANDLING AND STORAGE

 

Handling: Observe normal standards of industrial hygiene for handling chemicals. Use in a well ventilated

area. Avoid breathing vapour and contact with skin and eyes. Wear gloves, long sleeved shirt, and eye protection. A sensitised person should not be exposed to the product.

Storage: Store in tightly sealed containers to protect from atmospheric moisture. Store in a cool, dry area. Keep away from ignition sources such as fire, flame and sparks.

Empty container warning: Do not reuse empty drums or containers unless professionally cleaned. Do not cut, drill, grind or weld on or near empty containers.

Other Precautions: Do not eat, drink or smoke when using the product.

Duromastic ACS 2 (Liquid) MSDS

 

8. EXPOSURE CONTROLS / PERSONAL PROTECTION

 

Exposure Limit Information

NOHSC1

TWA STEL

Component (ppm) (mg/m3) (ppm) (mg/m3)

Acrylic polymer - a - -

Titanium dioxide - 10b - -

Additives - a - -

Water - a - -

a = not listed

b = as nuisance dust

c = per ACGIH

TWA = Time Weighted Average

STEL= Short term Exposure Limit

1 National Occupational Health and Safety Commission ( Australia)

Respiratory Protection

If vapours and mists occur, a respiratory protection program meeting Australian Standards AS- 1716 and AS-1715 requirements must be followed whenever workplace conditions warrant a respirator's use. None required if airborne concentrations are maintained below the exposure limit listed in "Exposure Limit Information"
 

Eye Protection

Use chemical splash goggles (Australian Standard AS-1337) or approved equivalent. Eye protection worn must be compatible with respiratory protection system employed. An eye wash station and safety shower should be available in the work area.

 
Hand Protection

Impermeable gloves as necessary to prevent skin contact. E.g. Nitrile or neoprene gloves.

 
Protective Clothing

Clothing made of the following material has excellent resistance : Tyvec, butyl Nitrile rubber or neoprene.

Engineering Controls (Ventilation)

Use local exhaust ventilation sufficient to maintain exposure levels below exposure limit concentrations. Refer to Australian Standard AS-1668.

 

9. PHYSICAL AND CHEMICAL PROPERTIES

 

Appearance and colour ...............................................White (un-tinted)

State ...........................................................................Low Viscous Liquid

Boiling point ................................................................100oC

Odour Characteristic ...................................................Mild Acrylic

Specific Gravity (Water = 1) ........................................1.05

Vapour Density (Air = 1) .............................................No Data Available

Vapour Pressure .........................................................30mm of Hg @ 25oC

Melting Point ...............................................................~0oC

Boiling Point ................................................................~100oC

Solubility in Water .......................................................Miscible.

Flash Point ................................................................ Not Applicable

Duromastic ACS 2 (Liquid) MSDS

 

10. STABILITY AND REACTIVITY

 

Considered stable under normal conditions of use and handling.

Hazardous decomposition products

Thermal decomposition may produce acrylic monomers, carbon monoxide, carbon dioxide and oxide of nitrogen.

 

11. TOXICOLOGICAL INFORMATION

 

Acute Data

No data available for the product.

 

12. ECOLOGICAL INFORMATION

 

No available data.

 

13. DISPOSAL CONSIDERATIONS

 

Do not reuse empty drums or containers unless professionally cleaned. Dispose of waste and empty containers in accordance with federal, state and local laws.

 

14. TRANSPORT INFORMATION

 

Not classified as Dangerous Goods according to the Australian Code For The Transport Of Dangerous Goods By Road And Rail (Sixth Edition). See section 1.

 

15. REGULATORY INFORMATION

 

No Available data.

 

16. OTHER INFORMATION

 

1 National Occupational Health and Safety Commission - Australia

2 Australian Code For The Transport Of Dangerous Goods By Road And Rail (Sixth Edition).

The advice and information contained herein is based on the original supplier's information.

 

Contractor | Backer Rod   |    Waterproof membrane    |   Drainage cell   |    Coating    | Protection Board   | Waterproof Bathroom | Waterproofing Primer   | Waterproofing Sealant | XPS Extruded Polystyrene | Phone: (02) 9660 8333  |  Fax: (02) 9692 8600  |  10 Hill Street, Leichhardt NSW 2040 Australia